lith turns S3 into a filesystem; what it asks of the box is a NIC and some RAM. Size for the reads you'll actually do.

The NIC is the ceiling for cold reads

A cold read streams from S3, so its throughput is bounded by the instance's network, not its CPU or disk. Pick the NIC first.

Watch burst-credit classes. Many instances advertise a burst bandwidth well above their sustained baseline; a short read rides burst, a long or many-file read drains the credits and settles at baseline. In measurement, a single cold sequential read of a >1 GiB object showed a post-first-window p99 latency of ~4.9 ms on a 30 Gbps c8gd.16xlarge (no burst model — advertised bandwidth is sustained) versus ~7.4 ms on a c8gd.4xlarge once its burst credits depleted — same code, different NIC headroom.

For sustained or multi-reader work, pick a class whose baseline meets your target, or a 16xlarge-and-up where the advertised bandwidth is sustained.

RAM sets the cache and the prefetch budget

lith serves reads from a bounded in-memory tier, default 25 % of system memory (--mem-cache), and lets prefetch hold up to 50 % of that un-demanded (--prefetch-budget). Two consequences:

  • Warm working set — a re-read is served from RAM only if it still fits the memory tier. With RAM ≳ 2× your working file, warm reads come from cache at ~20 GB/s.
  • Prefetch depth — the readahead window is bounded by the prefetch budget and shared fairly across open files, so a small-RAM box won't thrash under many concurrent readers.

RAM floor: below your working set, warm equals cold

A 14 GiB object never warms on a 4–8 GiB box — the memory tier there is only ~1.9 GiB (4 vCPU) or ~3.9 GiB (8 vCPU), far under the file. On those boxes the measured warm sequential rate equaled cold (~1.0–1.3 GB/s both), because every read missed the cache and refetched. Warm reuse needs RAM ≥ working set; plan for it or expect cold economics on every pass.

lith's own CPU cost is small

Serving bytes costs lith about 1.3 CPU-seconds per GB, roughly constant across box sizes (measured 1.2–1.6 for region, stream, and batch workloads, #77). At a ~100 MB/s cold fetch that's ≈13 % of one core — so even on a 2-vCPU box lith does not starve the application; the rest of the CPU goes to your code.

What it looks like, by class

Measured against s3://1000genomes in us-east-1, lith vs mountpoint-s3, all MB/s. Fair config: lith --disk-cache 0, --mem-cache 25 % of RAM; single = a 14 GiB CRAM read sequentially; 8-reader = eight 3.8–14 GiB CRAMs concurrently; warm = re-read from cache; metadata = 100k stats from a prebuilt index. Full per-run data in bench/results/, method in #52.

instance RAM NVMe cold seq (lith / mnt-s3) warm seq 8-reader (lith / mnt-s3) 100k stat warm rand4k
c8g.2xlarge 16 GiB no 1354 / 1527 1163 1550 / 1602 0.16 s, 0 S3 543k IOPS
c8gd.4xlarge 32 GiB yes 1440 / 1547 1400 1688 / 1637 0.17 s, 0 S3 —
c8gd.16xlarge 128 GiB yes 2848 / 2613 21383 3385 / 3221 0.16 s, 0 S3 589k IOPS

Reading guide: cold sequential is your NIC; warm and random are your cache; metadata is free. A single cold reader fills the NIC (readahead is sized to the bandwidth-delay product), reaching mount-s3 parity or better; the 8-reader aggregate reaches parity from a 16 GiB box up; warm reads come from RAM at ~20 GB/s once the working set fits; 100k stats take ~0.15 s with zero S3 requests. mount-s3 still edges cold single-reader on the smallest burst-credit boxes, where it rides NIC burst harder.

No NVMe?

Local instance-store NVMe (d classes) only helps when your working set exceeds RAM and you re-read it — point --disk-cache at the instance-store mount then. Otherwise leave --disk-cache off (the default) and rely on the memory tier plus the kernel page cache, or point --disk-cache at /dev/shm (tmpfs). Never put the disk cache on EBS, EFS, or NFS — caching a block there can be slower than refetching it from S3 in-region.

The smallest box that works

The crossover ladder found c8g.large (2 vCPU, EBS-only) runs selective, stream, and batch jobs cheaper than copying — so small is viable. But its cold sequential rate collapsed toward ~50 MB/s under sustained load once its burst credits were spent (a fresh box rides burst at ~1 GB/s).

So: a burst-credit class is fine for selective and short jobs and wrong for sustained streaming. For a long single-pass or many-reader run, pick a class whose baseline meets your demand. lith currently can't read the link speed on the c8g family, so it falls back to a conservative in-flight budget rather than sizing to the NIC — tracked in #79, the pending mitigation.

How lith sizes itself

lith derives its S3 concurrency from the bandwidth-delay product automatically (--inflight-bytes, default 2 × NIC bandwidth × 100 ms via ethtool). When the NIC speed can't be detected it uses a fixed fallback; set --inflight-bytes explicitly on those classes. The full set of levers is on the Knobs page.